Low-cost current monitor tracks high dc currents

( 01 Jul 2007 )
Susanne Nell, Breitenfurt, Austria; Edited by Brad Thompson and Fran Granville, EDN

To measure high levels of direct current for overload detection and protection, designers frequently use either a current-shunt resistor or a toroidal core and Hall-effect magnetic-field sensor. Both methods suffer from drawbacks. For example, measuring 20A with a 10-mΩ resistor dissipates 4W of power as waste heat. The Hall-effect sensor delivers accurate measurements and wastes little power, but it’s an expensive approach to simple current monitoring.

This Design Idea describes an inexpensive, low-power current-measurement circuit that’s useful for measurements of modest accuracy. As a bonus, a filter inductor in a dc/dc converter’s input line can double as a current sensor for the measurement circuit. A representative ferrite core’s permeability decreases as the core nears saturation (Figure 1). The curve’s shape and values depend on the core material’s characteristics and whether the core includes an air gap.

The core’s permeability depends on the magnetic-flux level in the ferrite material, which in turn depends on the amount of current flowing through the core’s windings. This circuit uses a simple LC oscillator to measure the core’s permeability. A primary winding comprising one or more turns wound on the core carries the measurement current. A multiturn secondary winding on the core forms an inductor, L, that determines the oscillator’s resonant frequency.

In theory, any LC oscillator circuit will serve in this application, but, in practice, the current-measurement winding presents a low impedance that damps the LC-tank circuit and causes start-up and stability problems in some oscillator circuits. Of a variety of tested oscillator circuits, the design in Figure 2 offers the best performance. A number of factors affect the core’s permeability, which in turn impacts the circuit’s frequency stability and limits its applications to current-overload detection and low-accuracy current measurements.

Figure 3 illustrates the circuit’s output-frequency-versus-current characteristics for three vendors’ ferrite cores of identical dimensions and number of secondary turns. For best linearity, use a low-hysteresis core material. Cores of virtually any dimensions and materials work in the circuit but require optimization of the number of turns on the oscillator tank and primary windings. Increase the core’s air gap, if present, when the current you apply to the core causes saturation before reaching the overload value. For improved performance and linear measurements, use the circuit in a closed-loop configuration (Reference 1).
Reference
Nell, Susanne


Click here for Illustrations:

Figure 1

Figure 2

Figure 3

 
Free Print Subscription Printer-friendly version Email to a Friend
Article Rating 
Average Rate:
 
Poor Quite Good Good Very Good Excellent
 
 
Related Content 
 
 
WEBCASTS
 
KNOWLEDGE CENTER
Panasonic Key Devices Guide 2008:
 
Fairchild Semiconductor :
 
 
Highest Rated  
 
Feedback Loop  
 
 
 
ADVERTISEMENT
Press Release 
 
TECHNOLOGY NEWS
 
RESOURCE CENTER


 
 
PRODUCT NEWS
 
FEATURED SPONSORS


 
 
 
DESIGN CENTERS
 
ADVERTISEMENT
     
Reference Designs 
   
     
 
 
 

 
 
RSS
   
   
   
   
   
   
   
   
   
   
   
   
   
   
   
   
   
   
   
   
   

POLL
What type of environmental regulation do you think will be most beneficial for the tech industry?
Proper recycling and disposal
Push for power efficiency and energy conservation
Chemical/lead regulation
View results
 
Outlook and Trends 2008


 

Reed Electronics Group | Reed Business Information Asia |
EDN India | EDN Taiwan | EDN Korea | EDN Japan | EDN China | EDN | EDN Europe
ECN Asia | ECN Taiwan | ECN Korea | ECN China | EB Asia | WDDA | WDDA Taiwan | WDDA China

 
ABOUT EDN Asia |