DC fans for forced-air convection cooling

Article By : Jeff Smoot

DC fans provide forced-air convection cooling and offer a range of options for better monitoring, control, and management of cooling.

DC fans are called upon by engineers in many situations and applications to provide forced-air convection cooling. Thanks to their widespread use, they are relatively easy to understand and can be implemented in a variety of configurations.

Their operation is ultimately rooted in basic physics in which moving air is effective in cooling objects by absorbing heat and transferring that heat to be dissipated. How much energy is transferred is reliant on several factors: the mass of the moving air, the specific heat of the moving air, and the temperature change imparted to the moving air.

illustration of hardware for natural convection and forced-air convection

Figure 1 This comparison of hardware shows the difference in natural convection and forced-air convection. Source: CUI Inc

When it comes to selecting a fan with sufficient size and airflow specifications, an engineer must conduct basic thermal analysis to determine the minimum airflow required. This thermal analysis typically includes modeling of heat sources, temperature rise, and ambient conditions, while also ensuring an efficient airflow path for the forced air.

Once the thermal analysis is complete and the proper fan or fans are selected, an engineer could simply connect the fans to a power source and allow them to provide constant forced-air cooling. However, in most cases, this approach is neither efficient nor effective long-term. Most fans today offer a range of options for better monitoring, control, and management. Understanding the options available can allow engineers to get the most out of their chosen fans and ensure better reliability of their overall system.

Basic on/off fan control

As mentioned above, running a fan full-time is a simple approach to thermal management that can certainly provide the necessary forced-air cooling in an application. However, this simplistic approach is not energy efficient as a constantly running fan uses the greatest amount of power and causes audible noise not suitable for every scenario. Fans also contain various moving parts with long, but finite life cycles that will wear down quicker during continuous operation.

On/off fan control is one such approach that can extend fan life by cycling the fan on and off when a cooling threshold or temperature setpoint is reached. Cycling the fan on and off saves power, can extend fan life, and reduces acoustic noise when the fan is not operating.

But on/off fan control is another method that is rather simplistic by nature and introduces its own set of limitations. From a thermal management standpoint, on/off fan control creates sequences of heating and cooling to the components being cooled. This thermal cycling can be a major factor in premature component failure because the differences in temperature-coefficients cause added stress on materials and joints. In fact, thermal cycling can be as detrimental or worse for components than operation at constant high temperatures.

Thermal overshoot can also come into play during the time a fan begins operating and the time the forced air begins cooling. Unless the “fan on” setpoint is set lower, overheating can occur while the cooling airflow catches up. Lastly, to limit on/off chattering around the setpoint temperature, hysteresis will need to be added.

The graph in Figure 2 was created to demonstrate thermal overshoot due to unavoidable thermal lag in on/off fan control applications. In the graph, the light blue line represents the desired setpoint temperature and includes a step change, the green line is the on/off cycling of the fan, and the dark blue line is the actual temperature.

graph show thermal overshoot and lag in on/off fan control applicationsFigure 2 Thermal overshoot and lag occur in on/off fan control applications. Source: CUI Inc

Fan protections and controls

Fans today are available with a range of controls and protections to help designers better optimize their thermal management systems. These controls can take the limitations of basic on/off control and improve upon performance, reliability, and efficiency. There are also protections available that detect fan problems early on, which can extend fan life and ensure systems are not put at risk. Let’s take a look at some of the most common fan controls and protections as well as their implementations.

Pulse-width modulation

Pulse-width modulation (PWM) is used to control and change the fan speed based on varying thermal conditions. As the first step toward improved fan performance, PWM-based variable-speed control results in better operating efficiency and can be implemented alongside advanced control algorithms. These algorithms can take into account usage patterns, energy costs, and more, while adapting to operational dynamics that match fan speed to thermal load.

This can be taken a step further by upgrading basic on/off fan control to the well-known proportional-integral-derivative (PI and PID) closed-loop control strategies. PI and PID controls help to avoid thermal undershoot or overshoot despite load changes by ensuring the airflow keeps conditions at the desired setpoint temperature.

Embedded tachometer signal

Sensing and reporting on a fan’s rotational speed via a pulsed signal, embedded tachometer is a control used for closed-loop feedback and more advanced fan control. Embedded tachometer also serves as a lock sensor if the fan seizes operation due to loss of power, obstructions, or any other reason. Having these detection capabilities is a major benefit to system operation, as the sooner negative conditions are detected, the quicker the system can be shut down or put in an inactive state to protect sensitive components.

Auto-restart protection

Auto-restart protection detects when the fan motor is prevented from rotating and automatically cuts the drive current. This serves to both protect fan-drive circuitry and indicate to the fan controller that there is a problem due to the drive current being cut-off.

Rotation detection/lock sensor

True to its name, rotation detection/lock sensor detects if a fan motor is operating or stopped in order to safeguard against problems at start-up or during operation.

Thermal management approach is critical

DC fans are a go-to solution in many thermal management systems, providing forced-air cooling to systems and keeping components within their operating limits. However, simply selecting a fan and running it full-time or using basic on/off control are short-sighted approaches to thermal management with fans. With a host of fan controls and protections, engineers can better optimize their forced-air cooling solutions for greater efficiency and reliability.

For more on thermal analysis and the selection process, see CUI Devices’ blog “Understanding Airflow Fundamentals for Proper Dc Fan Selection.”

This article was originally published on EDN.

Jeff Smoot is vice president for Application Engineering & Motion Control at CUI Inc.

Related articles:

Virtual Event - PowerUP Asia 2024 is coming (May 21-23, 2024)

Power Semiconductor Innovations Toward Green Goals, Decarbonization and Sustainability

Day 1: GaN and SiC Semiconductors

Day 2: Power Semiconductors in Low- and High-Power Applications

Day 3: Power Semiconductor Packaging Technologies and Renewable Energy

Register to watch 30+ conference speeches and visit booths, download technical whitepapers.

Leave a comment